One Stop Oem Solution Process
The valve control of second-hand high-frequency induction heating equipment does not need to be too large
by:Kehua
2022-08-04
Have you understood the environmental requirements for second-hand high-frequency induction heating equipment? When installing the water storage tank, the valve control does not need to be too large, otherwise it will be difficult to switch the furnace water to the water tank circulating water system, and the equipment is also It cannot be switched on at the same time as the generator set. Second-hand high-frequency induction heating equipment Second-hand high-frequency induction heating equipment The machine is installed outdoors. Every time the equipment starts to operate, the air conditioner must be turned on, and the water circulation of the equipment must be started. After the equipment is finished running, the air conditioner must be turned off, and the water cooling can be closed. However, the water circulation of the furnace body must be turned off after the furnace lining has dropped to room temperature. Second-hand high-frequency induction heating equipment use environment requirements Second-hand high-frequency induction heating equipment high-frequency heating furnace Kehua will tell you the use environment requirements of high-frequency induction heating equipment There are the following two points: install the generator set for the facility, install the backup generator set that may not have the capacity, not to mention that the switch of the pump tube bundle of the equipment can switch the power supply of the power grid and the power supply of the generator set quietly (preferably, the power grid and the generator set cannot be connected at the same time). Otherwise, it is easy to damage the generator set), and the generator set may be started to start the furnace body circulation pump to continue to work during a power outage. High-frequency induction heating equipment should be installed with two water pumps, one as the main water pump and the other as the backup water pump, which should be controlled by valves. If the motor of one water pump fails to burn out, it can be switched to another water pump for operation. 2. Install a water storage tank at the height of the building, and connect the water storage tank to the water inlet end of the furnace body through a valve, and the water inlet of the furnace body can be actively connected to the pool water and the water tank through the valve. Water, in the event of a sudden power failure, the furnace water circulation can be switched to the water tank circulating water system through the valve. The amount of water passing through the valve control does not need to be too large, so that the temperature of the furnace outlet water can not be boiled. Such a general and effective prevention of carbonization of furnace insulation rods due to power outages and water shortages. Second-hand high-frequency induction heating equipment The above is the relevant introduction about second-hand high-frequency induction heating equipment. I believe that friends who have read it carefully have understood it. When the equipment is finished, remember to close and block the water-cooling trivialities.
Custom message